LG Air Conditioners - air conditioning units for the ultimate in room temperature control   Air Conditioners and Air Conditioning Units installed and maintained South Africa
   Air Conditioners - Free Air Conditioners Quote | LG Air Conditioning Units Home   About Us   Testimonials   Advantages   Products   Gallery   Services   History   How It Works   Air Conditioner Quote   Contacts

  Products / Air Conditioners / LG Multiple Wall Mounted

LG Floor Standing Air Conditioner

Energy Saving Gold Fin Plasma Air Purifier

PDF Document LG Wall Mounted Type [171 KB]
LG South Arfica Air Conditioners


Features


Jet Cool:

In this mode quick and fast Cooling is done. Cold and high velocity air is supplied to the room till the indoor temperature reaches 18C.

Tele Control:

It provides you ease of control. Air conditioner can be switched on/off by the telephone. It saves time and energy.

Energy Saving Gold Fin:

Outdoor heat exchanger fins are coated with anticorrosive and hydrophilic layers. It prevents the corrosion of heat exchanger. Fins remain as new even after long time operation and maintains efficiency of heat exchanger constant. It also saves power and maintenance cost.

Plasma Air Purifier:

It not only removes microscopic contaminants and dust, but it also removes house mites, pollen, and pet fur to help prevent allergic diseases like asthma. It provides odor free, dust free and allergy free air.

Child Lock Function

It prevents the children or others from tampering with the control buttons on the unit. Unit can be controlled by the wireless remote controller.

Self Diagnosis Function:

This function provides diagnosis of the unit. An error code will be displayed on the LED display panel and diagnosis can be done as per the code indication.

Cooling Heating and Fan Operation:

LG Floor Standing type air conditioners can provide cooling, heating and fan operation. In the cooling mode, it cools the air with an operation range of 18~30C. In the heating mode, it heats the air with an operation range of 16~30C. In the fan operation mode, only indoor fan at the selected speed will run, outdoor fan and compressor will be off.

Electric Heater:

Electric Heater can be used to provide heat in addition to refrigerant cycle heat. It also provide and quick heating. It can also work as a stand alone heater with only fan operation.

Zero Standby Power:

Due to SMPS (Switching Modulation Power Supply) technology there is almost zero power consumption in the standby mode.

Auto Restart Operation:

Whenever there is an electricity failure to the unit, and after resumption of the power, unit will start in the same mode prior to the power failure. Memorized condition are on/off condition, operting mode (cooling/heating), set temperature and fan speed. The unit will memorize the above conditions and start with same memorized condition.

Hot Start Function :

During starting of the unit in the heating mode it prevents cold air blown from the unit. It starts the indoor fan only after indoor unit pipe temperature reaches a preset value(28C). When indoor unit pipe temperature has reached 28C, then for initial 1 minute the indoor fan runs at low speed and after that at the set fan speed.

Defrost / Deicing:

In the heating mode, it prevents the ice formation on the outdoor unit. The heating cycle is reversed to the cooling cycle to defrost the evaporator pipe of the outdoor unit. While defrost cycle, the compressor is on and indoor fan, outdoor fan and 4-way valve are off.

Soft Dry Operation:

During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 2C, the compressor OFF temperature is the setting temperature minus 1C. When the room temperature rises over the compressor ON temperature, the operation mode is switched to the Cooling mode. When the room temperature falls between the compressor ON temperature and OFF temperature, the operation mode is switched to the Soft Dry Operation.

Time Delay Safety Function:

It delays restarting of the compressor by three minutes, thereby preventing damage to the compressor.

Model No., Cooling btu/hr, Heating btu/hr

LM-1996B2L, 2x9,500, 2x9,500.

 
 
 
 
 
 
 
 
© Copyright 1 Stop Air Conditioning and Electrical Services 2010 - All Rights Reserved